Used AGILENT / HP / HEWLETT-PACKARD / KEYSIGHT E5091A #9280558 for sale

AGILENT / HP / HEWLETT-PACKARD / KEYSIGHT E5091A
ID: 9280558
Multiport test set.
AGILENT / HP / HEWLETT-PACKARD / KEYSIGHT E5091A is a high-performance network analyzer that enables precise characterization of radio-frequency (RF) and microwave components. It has a frequency range of 1 MHz to 26.5 GHz and can be used for various measurements such as gain and reflection coefficient, directivity, and return loss. HP E5091A features an intuitive user interface and a fast scan speed, allowing for quick and efficient testing. AGILENT E5091A has a vector network analyzer (VNA) that can measure the complex parameters of an RF or microwave component. The VNA uses a continuous sweep of frequencies and amplitude to measure the gain or reflection coefficient of the device. With the VNA, E5091A can also measure the return loss, directivity, insertion loss, group delay, and impedance of a device. KEYSIGHT E5091A also includes Advanced Jitter Measurements (AJM), a feature which can measure the effect of jitter on a equipment. HEWLETT-PACKARD E5091A consists of two integral measuring instruments, the device-under-test (DUT) and the testset. The DUT is the part of the system that is scanned. It can be an RF component, a network router, or a computer. The test set consists of two ports into which two RF cables are connected and used to measure the parameters of the DUT. AGILENT / HP / HEWLETT-PACKARD / KEYSIGHT E5091A uses Time Domain Analysis (TDA) process to measure the performance parameters. In this process, a continuous signal is sent through the unit and the return signals are then analyzed. TDA is the most accurate method for measuring a machine's performance and it allows for greater accuracy than frequency-domain analysis. HP E5091A has multiple measurement functions that include frequency-domain calibration, single-segment measurement and step-by-step measurement. Frequency-domain calibration is used to make sure the tool is properly calibrated. Single-segment measurement is used to measure parameters such as gain, reflection coefficient, and return loss. And lastly, step-by-step measurement is used to get the profile of a asset. AGILENT E5091A also comes with software, which includes custom drivers and integration with HP E5001A software environment. The software is compatible with Windows 2000 and newer systems and can be used to set a wide range of parameters and produce graphical reports of the results. Overall, E5091A is a high-performance, versatile network analyzer that is perfect for testing RF and microwave components. With its many measurement functions and its easy-to-use software, KEYSIGHT E5091A is a great choice for those looking for a reliable and accurate instrument.
There are no reviews yet