Used LIPTON 534 #179897 for sale

Manufacturer
LIPTON
Model
534
ID: 179897
Vintage: 1987
Autoclave Specifications: Interior dimensions: 33.5” x 60” Deep Maximum pressure: 330 PSI Pressure Rate: 0-10 PSI/Minute Average Depressurization Rate: 0-10 PSI/ Min. Average based on load Pressure Control Accuracy: +/- 1 PSI Maximum temperature: 800°F Heat source: Electric, 36kW Cooling: Water (process) cooling Electrical controls and recorder: Included Pressure components: Inlet and Exhaust Valve Pressure Transducer Monitoring and Data Acquisition Temperature: Maximum Design Temperature: 450°F @ 325 PSI Heating Rate: 0-10°F/Min based on air temperature and autoclave load Cooling Rate: 5°F/Min based on average air temperature and autoclave load from maximum working temperature to 150°F Customer must have cool water Temperature Control Accuracy and Uniformity: +/- 5° Door accessories: Door Safety Limit Switch Door Seal Door seal cooling water will be needed if operated above 450°F Hydraulically Operated Insulation Liner and 3” of Insulation Insulation: The interior of the autoclave will be insulated with 3” of high temp insulation The high temp insulation will be covered with stainless steel The autoclave will meet OSHA hot surface guidelines Temperature Monitoring Devices: (8) Thermocouple jacks with data acquisition included Cooling System: Modular cooling coil located in front of heat coil Requires cooling water equivalent to a 7.83 ton cooling tower to achieve 5 deg F per minute cool down based on the load indicated. Cooling tower included Vacuum System: 2 HP oil-free vacuum pump – 40 ACFM included (4) vacuum sense lines with transducers with 3 way valves for transducer calibration included PLC-controlled vacuum select valve 3 piece ball valve, stainless steel PLC controlled vent select valve, 3 piece ball valve stainless steel Stainless steel tubing ½” Vacuum probe transducer ports Exterior: Painted with heat and corrosion resistant primer and paint Controls: Windows based PC programmable control system (As per enclosed specs) For autoclave with the following features: (with no manual overrides) Control heating ambient – 450 Deg. F. at 0-10 Deg/Min F. Loaded based on 100 lb Product load and 150 lb tooling load Run at precise temperature ambient - 450 Deg. F. for programmed time period Total automatic control of cycle sequences from beginning to end. Operator controls for locking door. 1 psi door interlock Process complete and ready to open door indicator lights. Temperature and pressure safety back ups Full program editing and storage capabilities Thermocouples – quoted separately Vacuum Lines – quoted separately Remote monitoring of the system is available via Ethernet Connection Tracks: Track support and angle iron tracks provided. The tracks will be able to handle the customer supplied cart Cart is available at an additional cost Valves: Safety relief One Pressure transducer for controlling pressure Pressure switch for high pressure alarm Valves: Man-in-Cave Safety Switch Optional: Vacuum Line with: Two motorized ball valves Transducer with data collection Manual ball valve Pressure gauge Three way ball valve for transducer calibration Optional: Thermocouple jacks with data acquisition 2 HP vacuum pump 10 Ton cooling tower with controls, pump storage and storage tank 1987 vintage.
LIPTON 534 environmental chamber is a laboratory grade environmental testing and monitoring system designed for applications that require precise and repeatable control of temperature and humidity. It is ideal for applications such as biological sample testing, accelerated aging, stability studies, and material testing, as well as many other research and industrial applications. 534 Climate Chamber provides a wide range of temperature/humidity chambers, offering outstanding temperature/humidity control, reliability, and repeatability. LIPTON 534 offers multiple temperature and humidity operating modes, allowing for a variety of testing scenarios. It can operate in three separate temperature and humidity test chambers, allowing multiple samples to be tested simultaneously. 534 maintains an extremely accurate and precise temperature and humidity range via the use of PID controllers and state-of-the-art dual circulating fans. The PID controllers deliver precise temperature and humidity control and allow for real-time monitoring and recording of testing conditions. The dual circulating fans ensure that all corners are uniformly heated, eliminating any hot or cold spots. LIPTON 534 features a range of test functions, which include temperature cycling, step testing, and long-term stability testing. It also offers a variety of features for data logging and control during test procedures, such as control of start times, duration and duration profile, alarm functions, and alarm resetting. Data can be logged in internal memory or on a USB device, allowing for remote use. 534 can also be connected to a PC for automatic data downloads, allowing for efficient data transfer and manipulation. LIPTON 534 is designed with a high-grade stainless steel interior with a groundcoat epoxy-painted stainless steel exterior to combine superior durability and aesthetics. It also features an ergonomic design which allows for easy operation and maintenance. 534 has both top and side doors, providing easy access to the chamber during testing. The doors of LIPTON 534 are insulated using polyurethane-filled steel insulated material, providing excellent thermal efficiency. The chamber also features self-latching doors with integrated locks, providing added security and peace of mind. Overall, 534 environmental chamber offers a robust, accurate, and reliable climate test chamber for a variety of environmental testing purposes. It offers precise temperature and humidity control, efficient data logging and retrieval, and multiple temperature and humidity operating modes. With its high-grade stainless steel construction and insulation, as well as ergonomic design, LIPTON 534 is a reliable choice for any laboratory or industrial application.
There are no reviews yet