TERADYNE Catalyst
Manufacturer
TERADYNE
Model
Catalyst
ID: 149653
Tester Configuration: 2 processor system Processor 1: 450 MHz sparcv9 (online) Processor 3: 450 MHz sparcv9 (online) PCI based system Terabus is present TCI is present CATALYST_TH 1 BACKPLANE A #Slot Type Num XptA XptB Name 2 879-858-35 0 # 23 24 PLFD CC 3 879-858-25 0 # 21 22 PLFS CC 4 949-694-51 0 # 19 20 OVI CC 5 879-792-01 0 # 17 18 TIME CC 6 879-857-01 0 # 15 16 PMM CC-01 7 000-000-00 0 # 13 14 EMPTY 8 879-858-35 0 # 11 12 PLFD CC 9 000-000-00 0 # 9 10 EMPTY 10 949-681-50 0 # 7 8 VHFAWG400 DIFF CC 11 949-672-50 0 # 5 6 VHFDIG CC 14 879-858-35 0 # 25 26 PLFD CC 15 949-672-50 0 # 27 28 VHFDIG CC 16 000-000-00 0 # 29 30 EMPTY 17 000-000-00 0 # 31 32 EMPTY 18 949-643-00 0 # 33 34 TJD CC 19 949-838-20 0 # 35 36 WF (BBAC) CC 20 000-000-00 0 # 37 38 EMPTY 21 949-694-51 0 # 39 40 OVI CC 22 879-858-25 0 # 41 42 PLFS CC 23 879-858-35 0 # 43 44 PLFD CC 1 949-669-00 0 # 3 0 HAS (Left HAS LA669-00) 13 949-668-00 0 # 0 0 CATALYST HAC 12 949-667-00 0 # 0 0 DIF 24 949-669-01 0 # 4 0 HAS (Right HAS LA669-01) END RF_PIPES 1 # pipe-name slot schan description END # # Up to 4 Precision AC Card Cages are allowed # PRECISION_AC 1 #Slot Type Num Name 1 949-718-00 0 # PLFDIG TCI 2 879-764-01 0 # PLFSRC 3 879-779-00 0 # 1M SMEM 4 949-664-00 0 # VHFDIG MF 5 949-827-00 0 # VHFAWG 6 949-664-00 0 # VHFDIG MF 7 000-000-00 0 # EMPTY 8 949-671-00 0 # PACS CAGE INT END PRECISION_AC 2 #Slot Type Num Name 1 949-718-00 0 # PLFDIG TCI 2 879-764-01 0 # PLFSRC 3 879-779-00 0 # 1M SMEM 4 949-718-00 0 # PLFDIG TCI 5 949-718-00 0 # PLFDIG TCI 6 949-840-01 0 # WF (BBAC) 7 000-000-00 0 # EMPTY 8 949-671-00 0 # PACS CAGE INT END # # Up to 8 Universal Backplane/Synch Power Subsystem # cages are allowed # # For the Synch Power Subsystem: # Slot Type Name Instr1 # Instr2 # Ammeter # # # Instr1 # - insrument connected to the first two matrix lines # Instr2 # - insrument connected to the last two matrix lines # Ammeter # - ammeter connection # to AVOID errors, put NO 0 if no instrument is connected. # # UB_SPS_CAGE 1 # Slot Type Num Name 1 879-802-02 0 # UB_SPS_802 2 517-301-00 0 # UB_APU 3 517-301-00 0 # UB_APU 4 517-301-00 0 # UB_APU 5 517-301-00 0 # UB_APU 6 517-301-00 0 # UB_APU 7 517-301-00 0 # UB_APU 8 517-301-00 0 # UB_APU 9 517-301-00 0 # UB_APU 10 517-301-00 0 # UB_APU 11 517-301-00 0 # UB_APU 12 517-301-00 0 # UB_APU 13 517-301-00 0 # UB_APU 14 879-925-01 0 # UB_60_V_SRC MAT 1 15 879-925-01 0 # UB_60_V_SRC DUT 1 16 879-925-01 0 # UB_60_V_SRC MAT 2 17 879-925-01 0 # UB_60_V_SRC MAT 3 18 879-925-01 0 # UB_60_V_SRC MAT 5 19 879-925-01 0 # UB_60_V_SRC DUT 5 21 879-690-00 0 # UB_ASY 22 517-300-01 0 # UB_TJ300 END UB_SPS_CAGE 2 # Slot Type Num Name 1 879-802-02 0 # UB_SPS_802 2 949-700-01 0 # UB_OVI_CAL 1 3 949-693-01 0 # UB_OVI_CTRL 21 4 ?? ?? 4 949-698-01 0 # UB_OVI_AM 1 5 949-698-01 0 # UB_OVI_AM 2 6 949-698-01 0 # UB_OVI_AM 3 7 949-698-01 0 # UB_OVI_AM 4 22 517-300-01 0 # UB_TJ300 END HSD100_CHAN_CAGE 1 #Slot Type Num Fld1 Fld2 Name 1 949-921-01 0 # HSD CDM 400 2 949-921-01 0 # HSD CDM 400 3 949-921-01 0 # HSD CDM 400 4 949-921-01 0 # HSD CDM 400 5 949-820-10 0 # HSD CSB 6 949-921-01 0 # HSD CDM 400 7 949-921-01 0 # HSD CDM 400 8 949-921-01 0 # HSD CDM 400 9 949-921-01 0 # HSD CDM 400 END HSD100_CHAN_CAGE 2 #Slot Type Num Fld1 Fld2 Name 1 949-921-01 0 # HSD CDM 400 2 949-921-01 0 # HSD CDM 400 3 949-921-01 0 # HSD CDM 400 4 949-921-01 0 # HSD CDM 400 5 949-820-00 0 # HSD CSB 6 949-921-01 0 # HSD CDM 400 7 949-921-01 0 # HSD CDM 400 8 949-921-01 0 # HSD CDM 400 9 949-921-01 0 # HSD CDM 400 END HSD100_CHAN_CAGE 3 #Slot Type Num Fld1 Fld2 Name 1 949-921-01 0 # HSD CDM 400 2 949-921-01 0 # HSD CDM 400 3 949-921-01 0 # HSD CDM 400 4 949-921-01 0 # HSD CDM 400 5 949-820-00 0 # HSD CSB END CATALYST_TH 1 BACKPLANE B #Slot Type Num Name 25 949-625-00 0 # HSD DTH 26 949-625-00 0 # HSD DTH 27 949-625-00 0 # HSD DTH 28 949-625-00 0 # HSD DTH 29 949-626-10 0 # HSD THS 30 949-625-00 0 # HSD DTH 31 949-625-00 0 # HSD DTH 32 949-625-00 0 # HSD DTH 33 949-625-00 0 # HSD DTH 34 949-625-00 0 # HSD DTH 35 949-625-00 0 # HSD DTH 36 949-625-00 0 # HSD DTH 37 949-625-00 0 # HSD DTH 38 949-626-10 0 # HSD THS 39 949-625-00 0 # HSD DTH 40 949-625-00 0 # HSD DTH 41 949-625-00 0 # HSD DTH 42 949-625-00 0 # HSD DTH 43 949-625-00 0 # HSD DTH 44 949-625-00 0 # HSD DTH 45 949-625-00 0 # HSD DTH 46 949-625-00 0 # HSD DTH 47 949-626-20 0 # HSD THS/HCLK 48 949-625-00 0 # HSD DTH 49 949-625-00 0 # HSD DTH 50 949-625-00 0 # HSD DTH 51 949-625-00 0 # HSD DTH 61 949-625-00 0 # HSD DTH 62 949-625-00 0 # HSD DTH 63 949-625-00 0 # HSD DTH 64 949-625-00 0 # HSD DTH 65 949-626-00 0 # HSD THS 66 949-625-00 0 # HSD DTH 67 949-625-00 0 # HSD DTH 68 949-625-00 0 # HSD DTH 69 949-625-00 0 # HSD DTH 70 949-625-00 0 # HSD DTH 71 949-625-00 0 # HSD DTH 72 949-625-00 0 # HSD DTH 73 949-625-00 0 # HSD DTH 74 949-626-10 0 # HSD THS 75 949-625-00 0 # HSD DTH 76 949-625-00 0 # HSD DTH 77 949-625-00 0 # HSD DTH 78 949-625-00 0 # HSD DTH END # # Trigger Switch Yard # # Note: The logical slot numbers below correspond to the physical slot # numbers only for test systems which contain a TSY card # cage. In test systems which contain an SCS/TSY card cage the # mapping is: # # Logical TSY slot (below) Physical slot # 1 -> 2 # 3 -> 1 # TSY CAGE #Slot Type Num Name 1 879-655-02 0 # TSY 2 000-000-00 0 # EMPTY 3 879-671-01 0 # T_DELAY 4 000-000-00 0 # EMPTY END # # Time Subsystem # TIME_SUBSYSTEM # Board ID Serial # Name 879-793-00 # TMS Timer 879-794-01 # TMS Counter 879-795-01 # TMS Support END # # DC Subsystem - # # SRC <NUM> [1 - 13] # (sources 1-5 are MATRIX sources 1-5 # sources 6-13 are DUT sources 1-8) # HCU <NUM> *[1 - 4] # REF HCU <NUM> *[1 - 4] # HVSRC <NUM> *[1 - 4] # PWRSRC <NUM> [1 - 4] # DATABITS <NUM> - <NUM> [1 - 192] # # ** These instruments share the same seven-slot cage -- only one # instrument is allowed per slot. # DC_SUBSYSTEM # UBVI 60 1 ( 60V V/I Source in Universal Backplane 1 : slot 14) # UBVI 60 2 ( 60V V/I Source in Universal Backplane 1 : slot 16) # UBVI 60 3 ( 60V V/I Source in Universal Backplane 1 : slot 17) HCU 4 # UBVI 60 5 ( 60V V/I Source in Universal Backplane 1 : slot 18) # UBVI 60 6 ( 60V V/I Source in Universal Backplane 1 : slot 15) HCU 7 HCU 8 HCU 9 # UBVI 60 10 ( 60V V/I Source in Universal Backplane 1 : slot 19) DATABITS 1 - 48 # UB_MATRIX # # Testhead 1 # XPTs UB Cage Slot Type # 1-4 1 2 APU # 5-8 1 3 APU # 9-12 1 4 APU # 13-16 1 5 APU # 17-20 1 6 APU # 21-24 1 7 APU # 25-28 1 8 APU # 29-32 1 9 APU # 33-36 1 10 APU # 37-40 1 11 APU # 41-44 1 12 APU # 45-48 1 13 APU END.
TERADYNE Catalyst is a final test equipment designed by TERADYNE, one of the world's leading providers of Automatic Test Equipment (ATE). Catalyst provides high-throughput test solutions for the automotive, industrial, and consumer device manufacturers. The system is capable of testing for electrical, optical, acoustic, and thermal performances. Utilizing a scalable architecture designed for maximum uptime and low cost of ownership, TERADYNE Catalyst enables high performance for applications across industries. Catalyst's main features include its flexibility and expandability. It is designed with a highly-configurable platform that can be programmed and customized with automation, robotics, and data acquisition. Its multi-site, multi-level test capabilities are ideal for testing large numbers of product designs. Furthermore, TERADYNE Catalyst allows for enhanced test coverage, with user-configurable test programs that include multiple modules, verticals, and languages. Catalyst also offers a number of advanced features, such as advanced debugging, fast production start-up, sample-in-place testing (SiP), real-time data capture and analysis, high-speed fixture switching, and automation capabilities. Moreover, TERADYNE Catalyst has an advanced platform, allowing for multiple unit configurations depending on the user's application needs. In addition to its features, Catalyst is also highly reliable. Its enhanced fixtures, receptacles, and adapters are designed for maximum longevity and durability. Furthermore, its built-in safety features reduce the risk of failures that can cause costly downtime. TERADYNE Catalyst's superior performance, reliability, and scalability make it a suitable choice for the most challenging test applications. It can be easily operated in harsh environments, and is compliant with the most complex standards and specifications. In summary, Catalyst is a state-of-the-art final test machine with many advanced features for optimized performance and exceptional reliability. Its scalability and flexibility make it an ideal choice for any industry, and its superior safety features ensure a high level of product integrity and value.
There are no reviews yet