Used TERADYNE Catalyst #9213381 for sale

Manufacturer
TERADYNE
Model
Catalyst
ID: 9213381
Tester PPM / LVM / Vmem (M): 16 Meg Scan memory: Enable Frequency (MHZ): 100 Meg User computer: SUN BLADE 1500 Tester computer: SUN BLADE 2500 128 Digital channel (2) VHFAWG 400 DIFF (2) HF DIG TMS (7) UBVI 60 (6) AAPU CATALYST_TH 1 BACKPLANE A #Slot Type Num XptA XptB Name 2 000-000-00 0 # 23 24 EMPTY 3 000-000-00 0 # 21 22 EMPTY 4 000-000-00 0 # 19 20 EMPTY 5 879-792-01 0 # 17 18 TIME CC 6 000-000-00 0 # 15 16 EMPTY 7 949-681-50 0 # 13 14 VHFAWG400 DIFF CC 8 949-672-50 0 # 11 12 VHFDIG CC 9 000-000-00 0 # 9 10 EMPTY 10 949-681-50 0 # 7 8 VHFAWG400 DIFF CC 11 949-672-50 0 # 5 6 VHFDIG CC 14 803-594-00 0 # 25 26 UHFSRC CC 15 803-596-05 0 # 27 28 UWPORT 16 803-595-00 0 # 29 30 UWMM 17 000-000-00 0 # 31 32 EMPTY 18 803-596-05 0 # 33 34 UWPORT 19 803-594-00 0 # 35 36 UHFSRC CC 20 803-594-00 0 # 37 38 UHFSRC CC 21 000-000-00 0 # 39 40 EMPTY 22 000-000-00 0 # 41 42 EMPTY 23 000-000-00 0 # 43 44 EMPTY 1 949-669-00 0 # 3 0 HAS (Left HAS LA669-00) 13 949-668-00 0 # 0 0 CATALYST HAC 12 949-667-00 0 # 0 0 DIF 24 949-669-01 0 # 4 0 HAS (Right HAS LA669-01) END RF_PIPES 1 # pipe-name slot schan description Z8A 15 1 # UWPORT (OSP) Z7A 15 2 # UWPORT (OSP) Z6A 15 3 # UWPORT (OSP) Z5A 15 4 # UWPORT (OSP) Z4A 18 1 # UWPORT (OSP) Z3A 18 2 # UWPORT (OSP) Z2A 18 3 # UWPORT (OSP) Z1A 18 4 # UWPORT (OSP) END RF_CONNECTIONS 1 # RF pipe connections between channel cards # slot schan slot schan 14 1 to 15 5 16 3 to 15 7 19 1 to 18 5 20 1 to 18 6 16 1 to 18 7 END # # Up to 4 Precision AC Card Cages are allowed # PRECISION_AC 1 #Slot Type Num Name 1 949-664-00 0 # VHFDIG MF 2 949-827-00 0 # VHFAWG 3 000-000-00 0 # EMPTY 4 949-664-00 0 # VHFDIG MF 5 949-827-00 0 # VHFAWG 6 000-000-00 0 # EMPTY 7 949-320-00 0 # UWMS 8 949-671-01 0 # PACS CAGE INT END PRECISION_AC 2 #Slot Type Num Name 1 000-000-00 0 # EMPTY 2 000-000-00 0 # EMPTY 3 000-000-00 0 # EMPTY 4 000-000-00 0 # EMPTY 5 000-000-00 0 # EMPTY 6 000-000-00 0 # EMPTY 7 000-000-00 0 # EMPTY 8 949-671-01 0 # PACS CAGE INT END # # Up to 8 Universal Backplane/Synch Power Subsystem # cages are allowed # # For the Synch Power Subsystem: # Slot Type Name Instr1 # Instr2 # Ammeter # # # Instr1 # - insrument connected to the first two matrix lines # Instr2 # - insrument connected to the last two matrix lines # Ammeter # - ammeter connection # to AVOID errors, put NO 0 if no instrument is connected. # # UB_SPS_CAGE 1 # Slot Type Num Name 1 879-802-02 0 # UB_SPS_802 2 517-301-00 0 # UB_APU 3 517-301-00 0 # UB_APU 4 517-301-00 0 # UB_APU 5 517-301-00 0 # UB_APU 6 517-301-00 0 # UB_APU 7 517-301-00 0 # UB_APU 8 517-301-01 0 # UB_MATRIX 9 517-301-01 0 # UB_MATRIX 10 517-301-01 0 # UB_MATRIX 11 517-301-01 0 # UB_MATRIX 12 517-301-01 0 # UB_MATRIX 13 517-301-01 0 # UB_MATRIX 14 879-925-01 0 # UB_60_V_SRC MAT 1 15 879-925-01 0 # UB_60_V_SRC DUT 1 16 879-925-01 0 # UB_60_V_SRC DUT 2 17 879-925-01 0 # UB_60_V_SRC DUT 5 18 879-925-01 0 # UB_60_V_SRC DUT 6 19 879-925-01 0 # UB_60_V_SRC DUT 7 20 879-925-01 0 # UB_60_V_SRC DUT 8 21 879-690-00 0 # UB_ASY 22 517-300-01 0 # UB_TJ300 END HSD100_CHAN_CAGE 1 #Slot Type Num Fld1 Fld2 Name 1 949-921-01 0 # HSD CDM 400 2 949-921-01 0 # HSD CDM 400 3 949-921-01 0 # HSD CDM 400 4 949-921-01 0 # HSD CDM 400 5 949-820-10 0 # HSD CSB 6 949-921-01 0 # HSD CDM 400 7 949-921-01 0 # HSD CDM 400 8 949-921-01 0 # HSD CDM 400 9 949-921-01 0 # HSD CDM 400 END CATALYST_TH 1 BACKPLANE B #Slot Type Num Name 43 949-625-00 0 # HSD DTH 44 949-625-00 0 # HSD DTH 45 949-625-00 0 # HSD DTH 46 949-625-00 0 # HSD DTH 47 949-626-10 0 # HSD THS 48 949-625-00 0 # HSD DTH 49 949-625-00 0 # HSD DTH 50 949-625-00 0 # HSD DTH 51 949-625-00 0 # HSD DTH 61 949-625-00 0 # HSD DTH 62 949-625-00 0 # HSD DTH 63 949-625-00 0 # HSD DTH 64 949-625-00 0 # HSD DTH 65 949-626-00 0 # HSD THS 66 949-625-00 0 # HSD DTH 67 949-625-00 0 # HSD DTH 68 949-625-00 0 # HSD DTH 69 949-625-00 0 # HSD DTH END # # Trigger Switch Yard # # Logical TSY slot (below) Physical slot # 1 -> 2 # 3 -> 1 # TSY CAGE #Slot Type Num Name 1 879-655-02 0 # TSY 2 000-000-00 0 # EMPTY 3 000-000-00 0 # EMPTY 4 000-000-00 0 # EMPTY END # # Time Subsystem # TIME_SUBSYSTEM # Board ID Name 879-793-00 # TMS Timer 879-794-01 # TMS Counter 879-795-01 # TMS Support END # PACS_UW 1 # AWG UHFSRC MODSRC #Slot Type Rev Date Num Num Num Name 7 949-320-00 A 0412-0 1 2 1 # UWMS 7A 949-330-00 A 9944-0 # UWMS UP CONV 7B 000-000-00 0 0000-0 7C 949-333-00 C 0428-0 # UWMS MUX END # # # The UWPORT option modules are composed of plug-in modules. # The names list in the first column indicate the presence of # the option modules for the uwport. # UWPORT_OPTIONS_HEAD 1 # # Name Slot Type Rev Num Date PORT 15 803-596-05 1 # 0424-0 NOISE 15 733-104-00 1 # 9923-0 PORT 18 803-596-05 2 # 0306-0 NOISE 18 733-104-00 2 # 9923-0 END # # DC Subsystem - # # SRC <NUM> [1 - 13] # (sources 1-5 are MATRIX sources 1-5 # sources 6-13 are DUT sources 1-8) # HCU <NUM> *[1 - 4] # REF HCU <NUM> *[1 - 4] # HVSRC <NUM> *[1 - 4] # PWRSRC <NUM> [1 - 4] # DATABITS <NUM> - <NUM> [1 - 192] # # ** These instruments share the same seven-slot cage -- only one # instrument is allowed per slot. # DC_SUBSYSTEM # UBVI 60 1 ( 60V V/I Source in Universal Backplane 1 : slot 14) SRC 2 # UBVI 60 6 ( 60V V/I Source in Universal Backplane 1 : slot 15) # UBVI 60 7 ( 60V V/I Source in Universal Backplane 1 : slot 16) SRC 8 SRC 9 # UBVI 60 10 ( 60V V/I Source in Universal Backplane 1 : slot 17) # UBVI 60 11 ( 60V V/I Source in Universal Backplane 1 : slot 18) # UBVI 60 12 ( 60V V/I Source in Universal Backplane 1 : slot 19) # UBVI 60 13 ( 60V V/I Source in Universal Backplane 1 : slot 20) DATABITS 1 - 48 # UB_MATRIX # # Testhead 1 # XPTs UB Cage Slot Type # 1-4 1 2 APU # 5-8 1 3 APU # 9-12 1 4 APU # 13-16 1 5 APU # 17-20 1 6 APU # 21-24 1 7 APU # 25-28 1 8 Matrix # 29-32 1 9 Matrix # 33-36 1 10 Matrix # 37-40 1 11 Matrix # 41-44 1 12 Matrix # 45-48 1 13 Matrix END Checker Channels Executions Passes Fails % % Name Brief Full Total Pass Fail MAINFRAME UBST N/A 1 0 1 1 0 100.00 0.00 DCST N/A 1 0 1 1 0 100.00 0.00 MATRIXST N/A 1 0 1 1 0 100.00 0.00 STATIONST N/A 1 0 1 1 0 100.00 0.00 UBAPUST N/A 1 0 1 1 0 100.00 0.00 APUST N/A 0 0 0 0 0 0.00 0.00 ASYST N/A 0 0 0 0 0 0.00 0.00 HCUST N/A 0 0 0 0 0 0.00 0.00 APXFERLINST N/A 0 0 0 0 0 0.00 0.00 PWRVIST N/A 0 0 0 0 0 0.00 0.00 OVIST N/A 0 0 0 0 0 0.00 0.00 TEST HEAD 1 DATABUS_ST N/A 1 0 1 1 0 100.00 0.00 HEADST N/A 1 0 1 1 0 100.00 0.00 UBASYST N/A 1 0 1 1 0 100.00 0.00 HSCST N/A 0 0 0 0 0 0.00 0.00 TURBOACST N/A 0 0 0 0 0 0.00 0.00 TMSALST N/A 1 0 1 1 0 100.00 0.00 PMMST N/A 0 0 0 0 0 0.00 0.00 TRGST N/A 1 0 1 1 0 100.00 0.00 TMEMDLYST N/A 0 0 0 0 0 0.00 0.00 HSD_ST 128 1 0 1 1 0 100.00 0.00 TJDST N/A 0 0 0 0 0 0.00 0.00 BBACST N/A 0 0 0 0 0 0.00 0.00 PACSII_AMS_ST N/A 1 0 1 1 0 100.00 0.00 HFSAMPALST N/A 0 0 0 0 0 0.00 0.00 UHFCWST 3 1 0 1 0 1 0.00 100.00 MODSRCST N/A 1 0 1 0 1 0.00 100.00 UWST 2 1 0 1 0 1 0.00 100.00 VHFCWST N/A 0 0 0 0 0 0.00 0.00 VHFMMST N/A 0 0 0 0 0 0.00 0.00 VHFST N/A 1 0 1 1 0 100.00 0.00 VHF_AMS_ST N/A 1 0 1 1 0 100.00 0.00 GIGADIGST N/A 0 0 0 0 0 0.00 0.00 MODCLK_ST N/A 0 0 0 0 0 0.00 0.00 OVIDCCST N/A 0 0 0 0 0 0.00 0.00 PLFALST N/A 0 0 0 0 0 0.00 0.00 PLF_AMS_ST N/A 0 0 0 0 0 0.00 0.00 LFACST N/A 0 0 0 0 0 0.00 0.00 LFAC_AMS_ST N/A 0 0 0 0 0 0.00 0.00 VREGST N/A 0 0 0 0 0 0.00 0.00 RDC24ST N/A 0 0 0 0 0 0.00 0.00 LCAST N/A 0 0 0 0 0 0.00 0.00 SBCC_ST N/A 0 0 0 0 0 0.00 0.00 QVSDCCST N/A 0 0 0 0 0 0.00 0.00 QVSST N/A 0 0 0 0 0 0.00 0.00 GAZELLE_ST N/A 0 0 0 0 0 0.00 0.00.
TERADYNE Catalyst is a leader in the automated final test industry, providing both systems and automation solutions for high-volume production test applications. It enables the highest level of test program process automation and optimized accuracy, performance, and throughput. With several process options, including single-site and multi-site test, Catalyst is the ideal test solution for customers seeking a comprehensive, flexible, and most efficient test approach. TERADYNE Catalyst systems come with various integrated automation control capabilities, such as Gbelite, that regulate tool operation based on the status of the associated test equipment. This ensures synchronization across several test applications, even when operating on different test engines. This allows users to create complex multi-engine test processes with ease. Moreover, Catalyst systems are robust and boast superior levels of commonality and modularity, owing to their flexible platform and integrated subsystems. This enables users to quickly switch on new test requirements, quickly and cost-effectively. TERADYNE Catalyst features automated parametric test applications, which are designed to deliver fast and reliable results, regardless of type or complexity of the device under test. The system pairs the software with specialized hardware, which works together to quickly and accurately measure parameters, so users do not need to add additional hardware as device technology evolves. The unit also integrates advanced algorithms for device characterization, to ensure accurate measurements for a variety of test types. For enhanced production test throughput, Catalyst offers synchronized Multi-Site testing. This feature allows users to leverage two or more identical test systems and combine their power to speed up production tests. With the help of built-in automation tools, all configurations, test programs, and tests options can be easily setup and managed across different sites. Due to their superior levels of parallelism, multi-site tests typically deliver higher throughput than single site testsTERADYNE Catalyst offers advanced fault diagnostics to help users quickly detect and repair faulty devices, which helps reduce costs and improve overall customer satisfaction. Using innovative probing techniques, the machine has the ability to quickly analyze test results and pinpoint any potential issues with production device. This helps users reduce mean time to repair (MTTR) by quickly troubleshooting and repairing any faults. Overall, Catalyst is an automated final test tool that offers industry-leading capabilities and solutions to help users speed up their production tests, maximize accuracy, and reduce mean time to repair. Its robust platform, featuring integration, modularity, and automation control, helps users quickly and cost-effectively setup and manage complex test processes. With its advanced fault diagnostics, TERADYNE Catalyst provides users with an unmatched level of accuracy and efficiency.
There are no reviews yet