Used SUPERIOR AUTOMATION Wet bench #293597596 for sale
URL successfully copied!
Tap to zoom
ID: 293597596
Wafer Size: 8"
System, 8"
Tank 1:
Mega-sonic clean tank:
(25) Wafer process cassettes
Tank construction: Heated, Recirculating, Quartz
Four sided cascade overflow
Inlet / Outlet Connections, ½”
Connection: Flare
Tank inner dimension: 12” W x 12” L x 12” D
Mega-sonic system: 750 kHz, 600 W
Operating Temperature: 70°C
Manual lid: PTFE / Teflon
Tank 2 and 3:
SC2 Clean tank and Silicon etcher
(25) Wafer process cassettes
Tank construction: Recirculating PFA / Teflon
Four sided cascade overflow
Inlet / Outlet connections, ½”
Connection: Flare
Tank inner dimensions: 12” W x 12” L x 12” D
Manual lid: PTFE / Teflon
Tank 4 and 5:
HF and DHF:
(25) Wafer process cassettes
Four sided cascade overflow
Tank construction: Recirculating natural polypropylene
Inlet / Outlet connections, ½”
Connection: Flare
Tank I.D: 12” W x 12” L x 12” D
Manual lid: Natural polypropylene
Tank 6,7 and 8:
1, 2 and 3 QDR Rinse tank:
(25) Wafer process cassettes
Four sided cascade overflow
Tank construction: Natural polypropylene
DIW Adjustable: Top spray nozzle
DIW Bottom: Fill cascade overflow
Quick dump valve
Tank 9 and 10:
4 and 5 QDR Rinse tank:
(25) Wafer cassettes
Tank construction: Natural polypropylene
Four sided cascade overflow
DIW Adjustable: Top spray nozzle
DIW Bottom: Fill cascade overflow
Quick dump valve
QDR controller: Microprocessor
Integrated solenoid valve
Fill spray and dump timer.
A SUPERIOR AUTOMATION Wet bench is a type of laminar flow and fume hood. This equipment is typically placed in a laboratory setting and is designed to provide a contamination-free area in which to conduct essential handling tasks. It prevents airborne particulates and fumes from entering the workspace and provides an area with laminar flow, meaning that the air in the environment is kept at a lower pressure than the rest of the lab, allowing particles to be drawn away from the environment. Wet bench is an enclosed equipment designed to reduce contamination and provide a clean, safe workspace. This system is constructed of stainless steel, providing a robust and durable environment, and is typically built to include volumetric Flow Control, a double skinned wall unit, UV fluorescent lighting, and positive and negative pressure systems. This ensures even air pressure throughout the environment, minimizing any potential outside contamination from entering the workspace. The main component of SUPERIOR AUTOMATION Wet bench is a self-contained laminar flow work area which is free from any outside contamination such as dust, dirt, airborne particulates, and fumes. This is enabled by the machine's air circulation tool, where air circulates from an external source of clean air, flows through the interior of Wet bench, and is then filtered and exhausted back out to the outside environment. This helps to maintain a continuous laminar flow which is critical for any cleanroom processes. SUPERIOR AUTOMATION Wet bench is designed so that the air inside is kept at a lower pressure than the rest of the lab. This style of hood enables particles to be drawn away from the environment as they cannot be displaced against higher air pressure. It is also designed with a double skinned wall asset which further helps to improve air flow, reduce noise levels, and minimize heat loss. The lighting systems built into this Wet bench is designed to function using both direct and indirect UV fluorescent lighting, which provides a safe, even, and consistent light which is necessary for any precision tasks and cleanroom processes. Overall, the features of SUPERIOR AUTOMATION Wet bench provide a safe and contamination-free environment for laboratory tasks and processes. It ensures that air pressure is kept at a lower level than outside of the environment, and also has a double skinned wall model to help reduce exterior contamination. The lighting equipment is designed to provide even, safe and consistent sources of light, and the laminar flow ensures that airborne particulates and fumes do not enter the workspace. This is essential for any precision and contamination-free tasks that need to be conducted in the laboratory.
There are no reviews yet