Used AGILENT / HP / HEWLETT-PACKARD / KEYSIGHT 7890A #9351701 for sale

ID: 9351701
Gas Chromatograph (GC) system With 7000 GC / MS Triple quadrupole and GERSTEL Multi-Purpose Sampler (MPS) Agilent 7000 Triple quadrupole GC / MS: Ambient operating temperature: 15°C to 35°C Ambient operating humidity: 5% - 95% Storage extremes: -40°C - 70°C Line voltage requirements: ±10% of nominal One split flow turbomolecular vacuum pump Rotary vane foreline pump Independently MS heated ion source Chemical and electron-ionization modes (PCI / NCI / EI) (2) Independently MS heated hyperbolic quadrupole mass filters (1) Hexapole collision cell High-Energy Dynode (HED) Electron multiplier detector Independently GC Heated GC / MS Interface Independently GC Controlled collision cell gas flows High sensitivity electronic upgrades for the EI Source and HED Local Control Panel (LCP) for locally monitoring the MS GERSTEL Multi-Purpose Sampler (MPS) Multifunctional / Flexible autosampler Universal Syringe Module (USM) Proven MAESTRO software control Optimized tray design Sampler type: XYZ Robot with syringe-only conept Positioning accuracy: ±0.1mm System versions: MPS Liquid MPS Headspace MPS SPME Sample Capacity: 200 x 1 mL Vials per tray 98 x 2 mL Vials per tray 78 x 1 mL Vials per tray 32 x 10 mL / 20 mL Vials per tray 8 x 100 mL Vials per tray (4) Trays Thermostated sample trays: Temperature range: 4 - 200°C for 1 mL, 2 mL, 10 mL and 20 mL vials Cooling peltier or liquid Wash station solvents: 2 - 4 Solvent reservoirs: 10 - 1000 mL Agitators / Incubators: Positions: 2-15 Vials: 2 mL, 10 mL, 20 mL and 100 mL Temperature range: 10 - 200°C Agitation speed: 250 - 750 RPM (±15%) Stirring speed: 500 - 1500 RPM (±15%) Dilutor modules: Dilutor syringes: 1 mL, 2.5 mL, 5 mL and 10 mL 1000 mL Solvent reservoir Fiber bake-out station: Bake-out temperature maximum: 350°C 6 - 12 mL Interfaces: (2) AUX (2) Interfaces RS 232 LAN Wash station MODBUS For valve control Operating temperature: -40°C to 4°C Operating humidity: Relative humidity 75%, non-condensing Power: 100 / 240 VAC, 50 / 60 Hz, 120 W.
AGILENT / HP / HEWLETT-PACKARD / KEYSIGHT 7890A is a gas chromatograph (GC) spectrometer from HP. It is used to characterize components in a mixture by separating the compounds based on their differences in volatility and affinity for a stationary coating on the inner walls of a narrow tube, the column. This instrument features a pre-column injector, a column oven, a detector, a recording device, an alphanumeric keypad and a monitor. The injector is designed to throughly disperse sample and buffer solutions into the column to produce a better chromatographic resolution of the compounds. The oven is used to ensure a stable, temperature-controlled environment that maintains the flow rate and heat history of the sample. The detector of HP 7890A is a flame ionization detector (FID), typically used for hydrocarbon and organic compound analysis. This detector consists of a fuel cell, a flame, and a temperature monitoring probe. The fuel cell provides the fuel and oxidants that are injected into the flame to combust the sample gas components. The temperature monitoring probe measures the sample temperature and maintains it in the optimal range. The recording device of this instrument is a digital oscilloscope connected to a recorder. This device can detect even subtle changes in the signals of the detector and provide advanced post-sampling data. It also features digital filtering to reduce noise. Finally, AGILENT 7890A features an alphanumeric keypad and a monitor for controlling the instrument and monitoring all processes. The 80-character in-line alphanumeric keypad provides user with the ability to select columns, store data and run tests, experiment analyses, and review results. The monitor provides a visual display of the status of the instrument. 7890A is capable of delivering reliable, consistent and precise performance, with low detection limits for various compounds. In conclusion, HEWLETT-PACKARD 7890A is a GC spectrometer that offers users high-performance results for determining components in a mixture.
There are no reviews yet