Used APPLIED BIOSYSTEMS / ABI / MDS SCIEX 5600+ Triple TOF #9292304 for sale
URL successfully copied!
Tap to zoom
ID: 9292304
Mass spectrometer
With SHIMADZU Prominence UFLC
Accelerator TOF analyzer
AGILENT / HP / HEWLETT-PACKARD / KEYSIGHT 1200 Front-end LC system
Nitrogen generator
PC System
Oil pump
G1312A
G1379B
G1316A
G1367B Pal Autosampler
SHIMADZU uHPLC Front end:
LC-20ADXR
CBM-20A Lite
CTO-20AC
SIL-20ACXR
Mass range TOF: 40 kDa
Mass selection range Q1: 5 - 1250 m/z
TOF-MS Mass resolution: ≥35,000 (FWHM) at 956 m/z
Acquisition speed: 50 MS Accumulation time
TOF-MS / MS Mass resolution:
≥25,000 (FWHM) at 195 m/z
≥18,000 (FWHM) at 86 m/z
Acquisition speed: 50 MS Accumulation time
Detector type: 4 Channels MCP detector
With TDC signal processing for extended dynamic range
Flexible data acquisition workflows:
TOF-MS
Acquisition (IDA) MS/MS with fixed / Variable Q1 isolation windows
Targeted MRMHR workflow
Ionization sources:
Iondrive turbo V
Duospray source
TurboIon spray
Atmospheric-Pressure Chemical Ionization (APCI) probes
Digital pico-view nano-source
Orthogonal front end separation compatibility:
High-flow
Microflow
Nanoflow chromatography
Capillary Electrophoresis Spray Ionization (CESI)
SelexION differential ion mobility
Variable window SWATH acquisition:
Large number of Q1 isolation windows at user controlled widths
Upto 200 per cycle.
APPLIED BIOSYSTEMS / ABI / MDS SCIEX 5600+ Triple TOF (Time of Flight) Mass Spectrometer is an advanced, high-performance triple quadrupole (QQQ) system designed for the most discriminating quantitative and qualitative proteomic and metabolomic measurements. It achieves very high reproducibility, accuracy, and sensitivity, and is optimized for use with both liquid and gas chromatographic (LC and GC) platforms. The Triple TOF allows for easy, direct analysis of panel assays. Its mass range is greater than that of the classic quadrupole than anyone else, and its resolution is higher. Its sophisticated design also makes it a versatile tool for a variety of tasks, such as targeted and non-targeted qualitative and quantitative analyses, metabolite identification, protein identification and quantification, and proteomics. The Triple TOF is equipped with sophisticated hardware and software, such as the Apparatus Control Software (ACS), the Dynamic Flow Manager Pro (DFM-Pro) software, and ABI Acquisition Method Suite (AAMS). ACS provides a number of key features for the instrument, such as automated set-up and data collection; automated calibration and tuning; and all-in-one probe and interfacing control. DFM-Pro offers full control over the instrument flow, including sample collection, reagents, calibrants, methods, acquisition settings, and post-acquisition data processing. AAMS provides an efficient, user-friendly acquisition and analysis platform to greatly enhance the speed and accuracy of results. The Triple TOF is also designed to enhance performance, accuracy, and speed. It incorporates advanced ion trajectory technology and predictive diagnostics to significantly improve mass resolution, sensitivity, and repeatability. It also includes automated calibration and tuning; automated data collection and processing; a robust scanning range; and A2E sample introduction technology for clean, fast, and reproducible analyses. Additionally, it features both single-run and sequential methods for the highest levels of accuracy and sensitivity. The Triple TOF is capable of conquering a variety of research and clinical lab applications, across a range of atom masses and charge states. With its wide range of functions, advanced technology, and superior performance, ABI 5600+ Triple TOF Mass Spectrometer is one of the most advanced instruments on the market today.