Used SHIMADZU 2010 GC #165768 for sale
URL successfully copied!
Tap to zoom
ID: 165768
System with Single Split/Splitless Injector
Single Split/Splitless Injector
Single Flame Ionization Detector (FID)
Fast Oven Cooling Option
Automatic Pressure Control (APC)
110V/60Hz
User Manual
Available Options:
AOC 20i Autosampler with 150-Sample Tray
Single Wide Bore
Single Split/Splitless Injector
Clarity-Lite Data Acquisition Software
Shimadzu 2010 GC Starter Kit
Column Oven
Temperature Range (Ambient + 4°C) ~ 450°C (using LCO2 gas: -50°C – 450°C)
Inner Dimensions and Volume 280 (W) x 280 (H) x 175 (D) mm, 13.7L
Temperature accuracy ±1% of the set temperature in Kelvin unit (calibration at 0.01°C increments)
Temperature Variation Coefficient 0.01°C/°C
Temperature Program Steps Up to 20 (cooling program possible)
Programmed rate setting range -250°C ~ 250°C/min
Total time for all steps 9999.99 minutes max.
Injection Ports
Temperature Range Up to 400°C
Heating Settings 1°C steps
No. of units installed simultaneously Up to 3 units
Sample injection unit types Split/splitless injection is standard
Direct (without split) injection unit (option)
On-column/PTV (programmable temperature vaporizer)injection unit (option)
Flow Control Unit
Advanced Flow Controller (AFC)
Split/splitles injection mode and direct injection mode Pressure range: 0-970kPa
Programmable Steps 7 (Negative pressure step is available)
Programmed Rate Setting Range -400 ~ 400kPa/min
Split Ratio Range 0 – 9999.9
Mass Flow Rate Setting Range 0 – 1200mL/min
Constant Linear Velocity Maintains optimum separation at all times
Available Optional Accessories
AOC-20i Auto Injector Direct injection, PTV/LVI, 1 – 250 uL syringes, ambient headspace
AOC-20s Auto Sampler 150 1.5mL vials or 96 4mL vials and barcode reader
Leap Combi-Pal Autosampler SPME, headspace and micro-titer plate sampling capability
PY2020D Pyrolyzer Single or double shot includes autosampler
Detector Type(s) FID, TCD, ECD, FPD, FTD
Flame Ionization Detector (FID)
Temperature Range 450°C max.
Minimum detected quantity 3pgC/s (Dodecane)
Dynamic Range 107
Thermal Conductivity Detector (TCD)
Temperature Range 400°C max.
Dynamic Range 105
Sensitivity 20,000 mV – mL/mg (Decane)
Electron Capture Detector (ECD)
Temperature Range 350°C max.
Minimum detected quantity 8fg/s
Dynamic Range 104
Flame Photometric Detector (FPD)
Temperature Range 350°C max.
Dynamic Range P: 104
S: 103
Minimum detected quantity P: 0.2pgP/s (tributyl phosphate)
S: 4pgS/s (dodecane thiol)
Temperature Range 450°C max.
Dynamic Range N: 104
P: 104
Minimum detected quantity N: 0.2pgN/s (azobenzene)
P: 0.03pgP/s (malathion)
Maximum of 2 detectors to keep instrument performance.
SHIMADZU 2010 GC Gas Chromatograph is designed to enable precise, efficient and user friendly methods for sample analysis. This instrument is equipped with a turbo molecular pump and a ceramic micro hot-column design which allow for rapid analysis with no increase in background noise. The unit is equipped with both a flame ionization detector (FID) and a flame thermal conductivity detector (FCTD) for thorough sample analysis. The FID is capable of detecting volatile compounds down to the parts per trillion level and features high sensitivity, linearity and selectivity; while the FCTD is capable of detecting and measuring heavier compounds such as polycyclic aromatic hydrocarbons with excellent specificity and repeatability. A built-in intelligent controller enables precise conditions for sample analysis through automated calibration cycles and data entry. The efficient sample analysis capabilities of 2010 GC are further enhanced by dual injection modes for manual and semi-automated sampling as well as automated fraction collection. The output software system is able to monitor on-line data analysis and collection as well as record both historical and real-time settings for later analysis. SHIMADZU 2010 GC compares favorably amongst other gas chromatographs on the market with a number of features that make method development, operation and troubleshooting easier, such as loop flush, identification of equipment errors and status, built-in safety features, versatile programming and multiple sample introduction choices. This unit can be operated in a variety of locations such as laboratories and process industries. It is equipped with an ulraviolet-visible (UV/Vis) detector and can accommodate a variety of column lengths and diameters. Additionally, it has the ability to perform a wide range of separations such as temperature-programmable gas-liquid chromatography (TPGLC) and gas-solid chromatography (GS). All of these features, together with its large non-volatile memory and mass fingerprinting capabilities make 2010 GC a powerful, robust and versatile chromatography system, suitable for both qualitative and quantitative analyses.
There are no reviews yet