Used THERMO SCIENTIFIC ICP-MS #9384529 for sale

THERMO SCIENTIFIC ICP-MS
ID: 9384529
Mass spectrometer.
THERMO SCIENTIFIC ICP-MS (Inductively-Coupled Plasma Mass Spectrometry) is a type of mass spectrometer that is used widely in research and analytical laboratories for the detection and measurement of trace elements. The instrument measures the number and mass of ions present in a sample solution. This is done by using an inductively-coupled plasma torch to excite the sample solution, which is then ionized and directed by an optimized focusing equipment towards the mass analyzer. ICP-MS instrument works by ionizing the sample solution using a high temperature (7000K) and an intense electromagnetic field created by the plasma source. Once ionized, the ions then enter an electrostatic lensing system. The lensing unit contains four lenses that focus the ions towards the sample solution through an emission metal plate. These focused ions are then detected by the mass analyzer in the form of an ion beam, which is then measured and analyzed in terms of its mass to charge ratio. THERMO SCIENTIFIC ICP-MS instrument provides high sensitivity, excellent detection linearity, and low detection limits as compared to other analytical instruments of its type. It is capable of measuring elements within the range of 1 ppt (parts per trillion) and up to 10 ppm (parts per million). This makes ICP-MS highly suitable for qualitative and quantitative analysis of trace amounts of chemical species, and can be used in applications such as environmental analysis, forensic testing, and medical testing. THERMO SCIENTIFIC ICP-MS instruments are equipped with several features such as the Arduion Data Acquisition Machine (ADAS), which is an advanced data acquisition tool with computer-controlled operation, imaging systems that monitor the position of the ion beam and direct the mass spectra onto a CCD detector for data acquisition, and software for the control of ICP-MS. THERMO SCIENTIFIC ICP-MS systems also include an autosampler asset, which is designed to measure time-series samples automatically from single or multiple sources of samples. The model is fully automated, and can analyze up to 5 samples at a time, with each sample having a sample rate of approximately 200 samples/ hour. The equipment also includes a range of other features such as dynamic blank correction, enhanced background correction, and improved data management to ensure that the user obtains reliable and accurate results. In conclusion, ICP-MS system is an ideal tool for performing a wide variety of analytical tasks, with excellent sensitivity, linearity, and low detection limits, making it suitable for environmental, forensic, and clinical purposed. Coupled with its range of advanced features, the unit performs its job perfectly, providing users with precise and reliable data.
There are no reviews yet